261011T2350-heh - Rule engines: 12 called, 11 able to test, violations reported by 11
- Results: 2600 violations, 600 violators, 55 issues
- Download the full technical report (JSON)
History
- 34 days ago (oldest)
- 30 days ago (latest; this report)
Issues reported
Highest priority: 12
-
image not named
- Why it matters: User cannot get help to know what is in an image
- Priority: highest
- Related WCAG standard: 1.1.1
- Reported by 8 rule engines (Accessibility Checker + Axe + Editoria11y + Html Checker + Pour + QualWeb + SureA11y + WAVE)
- Results: 9 violations, 2 violators
-
contrast poor
- Why it matters: Content is difficult to understand
- Priority: highest
- Related WCAG standard: 1.4.3
- Reported by 6 rule engines (Accessibility Checker + Axe + HTML CodeSniffer + Pour + SureA11y + WAVE)
- Results: 588 violations, 185 violators
-
button not named
- Why it matters: User cannot get help explaining a button
- Priority: highest
- Related WCAG standard: 4.1.2
- Reported by 6 rule engines (Axe + HTML CodeSniffer + Pour + QualWeb + SureA11y + WAVE)
- Results: 38 violations, 8 violators
-
link not named
- Why it matters: User cannot get help understanding what a link points to
- Priority: highest
- Related WCAG standard: 2.4.4
- Reported by 5 rule engines (Accessibility Checker + Axe + Pour + QualWeb + SureA11y)
- Results: 5 violations, 1 violator
-
image link not named
- Why it matters: User cannot get help understanding what a link points to
- Priority: highest
- Related WCAG standard: 2.4.4
- Reported by 4 rule engines (Editoria11y + HTML CodeSniffer + QualWeb + WAVE)
- Results: 4 violations, 2 violators
-
control not named
- Why it matters: User cannot get help on how to operate a form item
- Priority: highest
- Related WCAG standard: 1.3.1
- Reported by 3 rule engines (Accessibility Checker + Pour + WAVE)
- Results: 9 violations, 9 violators
-
ID not unique
- Why it matters: User may be pointed to the wrong item
- Priority: highest
- Related WCAG standard: 4.1
- Reported by 3 rule engines (ASLint + Html Checker + HTML CodeSniffer)
- Results: 12 violations, 9 violators
-
svg image not named
- Why it matters: User cannot get help understanding an image
- Priority: highest
- Related WCAG standard: 1.1.1
- Reported by 2 rule engines (Accessibility Checker + ASLint)
- Results: 3 violations, 3 violators
-
label referent ineligible
- Why it matters: User cannot get help understanding an item in a form
- Priority: highest
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (Accessibility Checker)
- Results: 1 violation, 1 violator
-
requirement invalid
- Why it matters: User may fail to get help determining whether a form item must be completed
- Priority: highest
- Related WCAG standard: 1.3.5
- Reported by 1 rule engine (ASLint)
- Results: 1 violation, 1 violator
-
attribute value invalid
- Why it matters: Item behaves improperly
- Priority: highest
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (Html Checker)
- Results: 14 violations, 14 violators
-
autocomplete missing
- Why it matters: User cannot get help entering personal information in a form
- Priority: highest
- Related WCAG standard: 1.3.5
- Reported by 1 rule engine (Testaro)
- Results: 1 violation, 1 violator
High priority: 12
-
target very small
- Why it matters: User cannot reliably choose an item to click or tap
- Priority: high
- Related WCAG standard: 2.5.8
- Reported by 2 rule engines (Pour + SureA11y)
- Results: 3 violations, 3 violators
-
code obsolete
- Why it matters: Page contains code that is no longer standard
- Priority: high
- Related WCAG standard: 4.1
- Reported by 1 rule engine (Accessibility Checker)
- Results: 2 violations, 2 violators
-
forms not distinctly named
- Why it matters: User cannot get help on how some of the page is organized
- Priority: high
- Related WCAG standard: 1.3.6
- Reported by 1 rule engine (Accessibility Checker)
- Results: 2 violations, 2 violators
-
role invalid
- Why it matters: User cannot get help on the nature of an item
- Priority: high
- Related WCAG standard: 4.1.2
- Reported by 1 rule engine (Accessibility Checker)
- Results: 1 violation, 1 violator
-
attribute obsolete
- Why it matters: Page includes obsolete code that the browser may fail to process
- Priority: high
- Related WCAG standard: 4.1
- Reported by 1 rule engine (ASLint)
- Results: 2 violations, 1 violator
-
tab-opening link action unstated
- Why it matters: Following a link opens a new window, surprising a user
- Priority: high
- Related WCAG standard: 3.2.5
- Reported by 1 rule engine (Editoria11y)
- Results: 7 violations, 7 violators
-
autocomplete invalid
- Why it matters: User cannot get help entering personal information in a form item
- Priority: high
- Related WCAG standard: 1.3.5
- Reported by 1 rule engine (Html Checker)
- Results: 1 violation, 1 violator
-
box size absolute
- Why it matters: User cannot enlarge the content of an item for readability
- Priority: high
- Related WCAG standard: 1.4.4
- Reported by 1 rule engine (QualWeb)
- Results: 1 violation, 1 violator
-
small targets too near to each other
- Why it matters: User cannot reliably choose an item to click or tap
- Priority: high
- Related WCAG standard: 2.5.8
- Reported by 1 rule engine (Testaro)
- Results: 2 violations, 2 violators
-
input has placeholder instead of name
- Why it matters: User cannot get reliable help on what information to enter in a form item
- Priority: high
- Related WCAG standard: 4.1.2
- Reported by 1 rule engine (Testaro)
- Results: 1 violation, 1 violator
-
element focusability and operability conflict
- Why it matters: Keyboard-only user cannot operate an item
- Priority: high
- Related WCAG standard: 2.1.1
- Reported by 1 rule engine (Testaro)
- Results: 67 violations, 67 violators
-
element beyond display when focused
- Why it matters: Keyboard-only user cannot navigate properly to the operable items
- Priority: high
- Related WCAG standard: 1.4.10
- Reported by 1 rule engine (Testaro)
- Results: 4 violations, 4 violators
Low priority: 9
-
not exactly 1 h1 heading
- Why it matters: User cannot understand the topic of the page
- Priority: low
- Related WCAG standard: 1.3.1
- Reported by 3 rule engines (ASLint + Axe + Pour)
- Results: 3 violations, 1 violator
-
heading level skipped
- Why it matters: Helper misdescribes the page
- Priority: low
- Related WCAG standard: 1.3.1
- Reported by 3 rule engines (Axe + Html Checker + Pour)
- Results: 3 violations, 1 violator
-
main missing
- Why it matters: User cannot get help on how some of the page is organized
- Priority: low
- Related WCAG standard: 1.3.6
- Reported by 2 rule engines (Axe + Pour)
- Results: 2 violations, 1 violator
-
heading structure illogical
- Why it matters: Helper misdescribes the page
- Priority: low
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (HTML CodeSniffer)
- Results: 3 violations, 2 violators
-
links not grouped as nav
- Why it matters: User cannot get help identifying links as a navigation tool
- Priority: low
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (QualWeb)
- Results: 1 violation, 1 violator
-
line height low
- Why it matters: Text is difficult to read
- Priority: low
- Related WCAG standard: 1.4.8
- Reported by 1 rule engine (Testaro)
- Results: 7 violations, 7 violators
-
links named identically
- Why it matters: User cannot get help differentiating links
- Priority: low
- Related WCAG standard: 2.4.4
- Reported by 1 rule engine (Testaro)
- Results: 3 violations, 1 violator
-
page content moves spontaneously
- Why it matters: Motion-sensitive user may suffer harm
- Priority: low
- Related WCAG standard: 2.2.2
- Reported by 1 rule engine (Testaro)
- Results: 1 violation, 1 violator
-
focus indication improvable
- Why it matters: Keyboard-only user cannot easily choose an item to operate
- Priority: low
- Related WCAG standard: 2.4.7
- Reported by 1 rule engine (Testaro)
- Results: 144 violations, 144 violators
Lowest priority: 22
-
text contrast improvable
- Why it matters: Content is not easy to understand
- Priority: lowest
- Related WCAG standard: 1.4.6
- Reported by 6 rule engines (ASLint + Axe + HTML CodeSniffer + Pour + QualWeb + SureA11y)
- Results: 732 violations, 333 violators
-
content beyond landmarks
- Why it matters: User cannot get help on how some of the page is organized
- Priority: lowest
- Related WCAG standard: 1.3.6
- Reported by 3 rule engines (Accessibility Checker + Axe + Pour)
- Results: 386 violations, 311 violators
-
tab-opening link action unstated?
- Why it matters: Following a link opens a new window, possibly surprising a user
- Priority: lowest
- Related WCAG standard: 3.2.5
- Reported by 3 rule engines (ASLint + Pour + Testaro)
- Results: 287 violations, 164 violators
-
role redundant
- Why it matters: Page includes unnecessary code
- Priority: lowest
- Related WCAG standard: 4.1.2
- Reported by 2 rule engines (Accessibility Checker + Pour)
- Results: 2 violations, 1 violator
-
aria attribute redundant
- Why it matters: Page includes unnecessary code
- Priority: lowest
- Related WCAG standard: 4.1.2
- Reported by 2 rule engines (Accessibility Checker + Pour)
- Results: 2 violations, 1 violator
-
link name vague
- Why it matters: User may misunderstand what a link points to
- Priority: lowest
- Related WCAG standard: 2.4.4
- Reported by 2 rule engines (ASLint + Pour)
- Results: 23 violations, 23 violators
-
element referenced by multiple labels
- Why it matters: User cannot get reliable help on the topics of form items
- Priority: lowest
- Related WCAG standard: 1.3.1
- Reported by 2 rule engines (ASLint + WAVE)
- Results: 4 violations, 3 violators
-
button name not visible
- Why it matters: User cannot get help explaining a button
- Priority: lowest
- Related WCAG standard: 4.1.2
- Reported by 1 rule engine (ASLint)
- Results: 9 violations, 5 violators
-
title attribute empty
- Why it matters: Hovering does not get the promised explanation of an item
- Priority: lowest
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (ASLint)
- Results: 1 violation, 1 violator
-
fieldset missing?
- Why it matters: User may be unable to get help recognizing a group of related form items
- Priority: lowest
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (ASLint)
- Results: 2 violations, 2 violators
-
labeling risky
- Why it matters: User may misunderstand a form control
- Priority: lowest
- Related WCAG standard: 3.3.2
- Reported by 1 rule engine (ASLint)
- Results: 2 violations, 2 violators
-
target small
- Why it matters: User cannot reliably choose an item to click or tap
- Priority: lowest
- Related WCAG standard: 2.5.5
- Reported by 1 rule engine (Pour)
- Results: 15 violations, 15 violators
-
text contrast not testable
- Why it matters: Text may be difficult to read
- Priority: lowest
- Related WCAG standard: 1.4.3
- Reported by 1 rule engine (QualWeb)
- Results: 106 violations, 106 violators
-
event not keyboard-triggerable?
- Why it matters: Keyboard-only user may be unable to perform an action
- Priority: lowest
- Related WCAG standard: 2.1.1
- Reported by 1 rule engine (QualWeb)
- Results: 3 violations, 3 violators
-
label location dubious
- Why it matters: User may fail to notice the explanation of an item in a form
- Priority: lowest
- Related WCAG standard: 3.3.2
- Reported by 1 rule engine (QualWeb)
- Results: 2 violations, 2 violators
-
all-italic text
- Why it matters: Text is difficult to read
- Priority: lowest
- Related WCAG standard: 3.1.5
- Reported by 1 rule engine (Testaro)
- Results: 15 violations, 15 violators
-
large visible-element count
- Why it matters: User cannot easily find items in the page
- Priority: lowest
- Related WCAG standard: 2.4
- Reported by 1 rule engine (Testaro)
- Results: 1 violation, 1 violator
-
text distortion
- Why it matters: Text is difficult to read
- Priority: lowest
- Related WCAG standard: 3.1.5
- Reported by 1 rule engine (Testaro)
- Results: 3 violations, 3 violators
-
role assigned instead of implicit
- Why it matters: User may misunderstand the purpose of an item
- Priority: lowest
- Related WCAG standard: 4.1.2
- Reported by 1 rule engine (Testaro)
- Results: 3 violations, 3 violators
-
inconsistent heading, link, or button styles
- Why it matters: User cannot easily distinguish items of different types
- Priority: lowest
- Related WCAG standard: 3.2.4
- Reported by 1 rule engine (Testaro)
- Results: 3 violations, 1 violator
-
title attribute invalid
- Why it matters: User gets too little, too much, or repeated help explaining an item
- Priority: lowest
- Related WCAG standard: 1.3.1
- Reported by 1 rule engine (Testaro)
- Results: 35 violations, 35 violators
-
z-index not zero
- Why it matters: User cannot predict the effect of clicking
- Priority: lowest
- Related WCAG standard: 1.4
- Reported by 1 rule engine (Testaro)
- Results: 19 violations, 19 violators
What you can do
Choose how to address these issues:
Do it yourself
Explore the issues, following the links above. Decide which issues are actual defects. Plan and implement corrections. Then retest the page.
Use artificial intelligence
Make Kilotest available to an AI assistant. Then give it a prompt like this:
Kilotest reports issues on the Society for Evidence Based Gender Medicine home web page. Describe them and propose a plan to resolve the genuine defects.